Skip to main content
AAV capsid structure 3D illustration showing protein coat assembly, multiple particles against dark background.
Article

Shift AAV Quality Assessment to the Bioreactor

How a column-free technique yields accurate empty, partial, and full capsid ratios direct from clarified lysate.

Brought to you byRefeyn

Optimizing adeno-associated virus (AAV) vector production means making critical decisions without capsid-loading data. Matrix noise in unpurified culture defeats single-particle detection, and established light-scattering and sedimentation assays demand high titers. These analytical limits push assembly checks downstream, often after the next production cycle has begun.

This application note provides a bench-scale cleanup protocol that moves capsid-ratio assessment to the bioreactor stage in three hours. Mass photometry resolves the constituent capsid populations from 1.5mL of prepared culture. Results match those from a full downstream purification run.

Download this application note to 

  • See how a capture, wash, and elution procedure isolates capsids from cell culture background
  • Benchmark data comparing mass photometry against size-exclusion and sedimentation methods
  • Review equivalence data across AAV8 and AAV9 preparations 

Sponsored by

  • Refeyn

Top Image Credit:

©iStock, Dr_Microbe

The Scientist Digest cover September 2026
September 2026

Multiplex Microscopy Becomes Easier with Encoded Antibodies

A new system that enables researchers to uniquely tag monoclonal antibodies for use in microscopy could help simplify complex imaging studies.

View this Issue
Essential Genes Are Dominantly Activated by Single Transcription Factors

Essential Genes Are Dominantly Activated by Single Transcription Factors

EpiCypher Logo
Rethinking ALS Biomarkers: From Discovery to Clinical Impact

Rethinking ALS Biomarkers: From Discovery to Clinical Impact

Alamar Biosciences logo
Engineering CAR-Neutrophils In Vivo to Target Glioblastoma

Engineering CAR-Neutrophils In Vivo to Target Glioblastoma

Miltenyi
Best Practices for qPCR Assay Design and Optimization

Best Practices for qPCR Assay Design and Optimization

Bio-Rad

Products

Closeup image of a multi channel pipette dispensing pink liquid into a 96-well plate.

The ASSIST PLUS pipetting robot for affordable workflow automation

Integra Logo
Single cells in suspension

Rapidly isolate primary cells and make uniform single-cell suspensions with Corning® Cell Strainers

Corning logo
Abstract image representing cell membranes linked together.

CellBrite® Steady Membrane Stain: Cell surface staining built for real-time imaging

Biotium
sino biological logo

Monod Bio Licenses AI-designed Protein Technologies to SignalChem Biotech for Custom Discovery Assays